Customization: | Available |
---|---|
After-sales Service: | Online/ Video/ on-Site Guidance and Training |
Warranty: | 1year |
Still deciding? Get samples of US$ 35.2/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Optional Features
·Register sealed type: Dry type; Semi-dry type; Super-dry type.
·Accuracy: R=80 ; 100; 125; 160;class b;class c.
·Size: 15~50mm.
·Hot water.
·Non return valve.
·Reed switch option.
·Several lengths and connections availavle on request.
·Thread end type: BSP / NPT.
·Materials: Brass,Brass interface,Brass material
·Brass working pressure: PN16(16bar)
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Features
·Multiple jets: As the name suggests, multi-jet water meters have multiple jets or nozzles arranged symmetrically around the meter's measuring chamber. These jets create a symmetrical flow pattern, ensuring accurate measurements even in low-flow scenarios.
·Rotating impeller: Inside the measuring chamber, there is a rotating impeller that is driven by the water flow. The impeller's rotation is proportional to the water velocity, allowing for precise measurement of the water volume passing through the meter.
·Magnetic coupling: Multi-jet water meters often use a magnetic coupling system to transmit the impeller's rotation to the register or dial mechanism outside the meter body. This eliminates the need for direct mechanical contact, reducing the chances of wear and tear and ensuring a longer lifespan.
·Wide flow range: Multi-jet water meters are designed to measure a wide range of flow rates accurately. They can effectively record both low and high flow rates, making them suitable for various applications, including residential, commercial, and light industrial settings
Standards Compliance
Technical data conform to international standard ISO 4064.
Working Conditions
·Water temperature: 0.1ºC~50ºC for cold water meter.
·Water pressure: ≤1.6Mpa (16 bar).
DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | |
Size(inch) | 1/2" | 3/4" | 1" | 1-1/4" | 1-1/2" | 2" | |
Q4(l/h) | 3125 | 5000 | 7875 | 12500 | 20000 | 31250 | |
Q3(l/h) | 2500 | 4000 | 6300 | 10000 | 16000 | 25000 | |
R=80 | Q2(l/h) | 50 | 80 | 126 | 200 | 320 | 400 |
Q1(l/h) | 31.25 | 50 | 78.75 | 125 | 200 | 250 | |
R=100 | Q2(l/h) | 40 | 64 | 100.8 | 160 | 256 | 400 |
Q1(l/h) | 25 | 40 | 63 | 100 | 160 | 250 | |
R=125 | Q2(l/h) | 32 | 51.2 | 80.64 | 128 | 204.8 | 200 |
Q1(l/h) | 20 | 32 | 50.5 | 80 | 128 | ||
R=160 | Q2(l/h) | 22.5 | 40 | 63 | 100 | 160 | 400 |
Q1(l/h) | 15.62 | 25 | 39.37 | 62.5 | 100 | 250 | |
Max.Reading(m³) | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | |
Min.Reading(Liter) | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | |
Max.Pressure(Bar) | 16 | 16 | 16 | 16 | 16 | 16 | |
Pressure Loss | 63 | ||||||
Max.Temperature | T=50/90 | ||||||
Pulse Output Option | Vmax=24V | ||||||
Imax=100mA | |||||||
Pmax=2W |
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.