Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| After-sales Service: | Online/ Video/ on-Site Guidance and Training |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
What is the difference between a multi-jet water meter and a single-jet water meter?
| Item | multi jet water meter | single water meter |
| Water flow impact method | Multiple water jets impact the impeller tangentially and evenly from different directions, keeping the impeller balanced | A single jet of water impacts the impeller from one side. |
| Impeller Stability | Balanced forces, smooth impeller rotation, no significant uneven wear | Concentrated forces, impeller prone to "eccentric wear" due to axial force, stability decreases after long-term use |
| Pressure Loss | Smaller (due to multiple flow channels diverting the flow, with resistance dispersed) | Larger (single flow channel with concentrated force, resistance concentrated) |
| Cost | Medium (multi-channel design, high precision requirements for components) | Low (simple structure, fewer parts, easy manufacturing process) |

|
DN (mm)
|
15 | 20 | 25 | 32 | 40 | 50 | 50 |
|
Size (inch)
|
1/2"
|
3/4''
|
1"
|
1-1/4"
|
1-1/2''
|
2''
|
2"
|
|
Length (L)
|
165/190 | 190 | 260 | 260 | 300 | 300 | 280 |
|
Width (W)
|
95 | 98 | 103.5 | 103.5 | 125 | 125 | 160 |
|
Height (H)
|
116 | 117 | 124 | 124 | 162 | 162 | 187.5 |
|
Connecting
Thread D
|
G3/4B
|
G1B
|
G11/4B
|
G11/2B
|
G2B
|
G21/2B
|
Flange
end
|
|
Nominal Diameter (mm)
|
15 | 20 | 25 | 32 | 40 | 50 | |
|
Size (inch)
|
1/2"
|
3/4"
|
1"
|
1-1/4"
|
1-1/2''
|
2"
|
|
|
Q4(l/h)
|
3125
|
5000
|
7875 | 12500 | 20000 | 31250 | |
|
Q3(l/h)
|
2500
|
4000 | 6300 | 10000 | 16000 | 25000 | |
|
R=80
|
Q2 (l/h)
|
50
|
80 | 126 | 200 | 320 | 500 |
|
Q1 (l/h)
|
31.25
|
50 | 78.75 | 125 | 200 | 312.5 | |
|
R=100
|
Q2 (l/h)
|
40 | 64 | 100.8 | 160 | 256 | 400 |
|
Q1 (l/h)
|
25 | 40 | 63 | 100 | 160 | 250 | |
| R=125 | Q2 (l/h) | 32 | 51.2 | 80.64 | 128 | 204.8 | 320 |
| Q1 (l/h) | 20 | 32 | 50.5 | 80 | 128 | 200 | |
| R=160 | Q2 (l/h) | 25 | 40 | 63 | 100 | 160 | 250 |
| Q1 (l/h) | 15.62 | 25 | 39.37 | 62.5 | 100 | 156.25 | |
|
Max. Reading (m3)
|
99,999
|
99,999
|
99,999 | 99,999 | 99,999 | 99,999 | |
|
Min.Reading (Liter)
|
0.05
|
0.05
|
0.05 | 0.05 | 0.05 | 0.05 | |
|
Accuracy Class
|
Class2
|
||||||
|
Temperature Class
|
T50/T90
|
||||||
|
Maximum Admissible
Pressure
|
PN16
|
||||||
|
Pressure Loss Classes
|
0.63bar
|
||||||
|
Pulse Output Option
|
Vmax=24V
|
||||||
|
Imax=100mA
|
|||||||
|