Customization: | Available |
---|---|
After-sales Service: | Online/ Video/ on-Site Guidance and Training |
Warranty: | 1year |
Still deciding? Get samples of US$ 35.2/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Optional Features
·Register sealed type: Dry type; Semi-dry type; Super-dry type.
·Accuracy: R=80 ; 100; 125; 160;class b;class c.
·Size: 15~50mm.
·Hot water.
·Non return valve.
·Reed switch option.
·Several lengths and connections availavle on request.
·Thread end type: BSP / NPT.
·Materials: Brass,Brass interface,Brass material
·Brass working pressure: PN16(16bar)
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Features
·Multi-jet design: Multi Jet Water Meters utilize a multi-jet impeller design, which ensures even distribution of water around the impeller. This design improves accuracy, especially at low flow rates, by reducing the possibility of blockages or sticking caused by debris in the water.
·Wide flow range: These meters are capable of measuring a wide range of flow rates, making them suitable for various applications, including residential, commercial, and industrial settings. They can accurately measure both high and low flow rates, ensuring reliable performance in different scenarios.
·Accuracy: Multi Jet Water Meters are known for their accuracy in measuring water consumption. Their design and impeller mechanism contribute to precise measurement, allowing for accurate billing and resource management.
·Durability: These meters are designed to withstand harsh environments and long-term use. They are typically made from durable materials such as brass or bronze, which provide resistance against corrosion and extend the meter's lifespan.
DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | |
Size(inch) | 1/2" | 3/4" | 1" | 1-1/4" | 1-1/2" | 2" | |
Q4(l/h) | 3125 | 5000 | 7875 | 12500 | 20000 | 31250 | |
Q3(l/h) | 2500 | 4000 | 6300 | 10000 | 16000 | 25000 | |
R=80 | Q2(l/h) | 50 | 80 | 126 | 200 | 320 | 400 |
Q1(l/h) | 31.25 | 50 | 78.75 | 125 | 200 | 250 | |
R=100 | Q2(l/h) | 40 | 64 | 100.8 | 160 | 256 | 400 |
Q1(l/h) | 25 | 40 | 63 | 100 | 160 | 250 | |
R=125 | Q2(l/h) | 32 | 51.2 | 80.64 | 128 | 204.8 | 200 |
Q1(l/h) | 20 | 32 | 50.5 | 80 | 128 | ||
R=160 | Q2(l/h) | 22.5 | 40 | 63 | 100 | 160 | 400 |
Q1(l/h) | 15.62 | 25 | 39.37 | 62.5 | 100 | 250 | |
Max.Reading(m³) | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | |
Min.Reading(Liter) | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | |
Max.Pressure(Bar) | 16 | 16 | 16 | 16 | 16 | 16 | |
Pressure Loss | 63 | ||||||
Max.Temperature | T=50/90 | ||||||
Pulse Output Option | Vmax=24V | ||||||
Imax=100mA | |||||||
Pmax=2W |