Customization: | Available |
---|---|
After-sales Service: | Free After-Sales Support |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 8.6/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Optional Features
·Register sealed type: Dry type; Semi-dry type; Super-dry type.
·Accuracy: R=80 ; 100; 125; 160;class b;class c.
·Size: 15~50mm.
·Cold water.
·Non return valve.
·Reed switch option.
·Several lengths and connections availavle on request.
·Thread end type: BSP / NPT.
·Materials: Plastic
·Plastic Working pressure: PN10(10bar)
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Features
·Magnetic Drive, Lower transmission resistance.
·Magnetic shield, for external magnetic field protection.
·Sealed dry register ensures long time clear reading.
·External regulating device.
Accressories: 2pcs coupling, 2pcs coupling nuts and 2pcs washers.
·With high accuracy
·For horizontal use
·Accessories include Strainer, Rotary piston, Connection Widget, connector fitting
Standards Compliance
Technical data conform to international standard ISO 4064.
Working Conditions
·Water temperature: 0.1ºC~50ºC for cold water meter.
·Water pressure: ≤1.6Mpa (16 bar).
DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | |
Size(inch) | 1/2" | 3/4" | 1" | 1-1/4" | 1-1/2" | 2" | |
Q4(l/h) | 3125 | 5000 | 7875 | 12500 | 20000 | 31250 | |
Q3(l/h) | 2500 | 4000 | 6300 | 10000 | 16000 | 25000 | |
R=80 | Q2(l/h) | 50 | 80 | 126 | 200 | 320 | 400 |
Q1(l/h) | 31.25 | 50 | 78.75 | 125 | 200 | 250 | |
R=100 | Q2(l/h) | 40 | 64 | 100.8 | 160 | 256 | 400 |
Q1(l/h) | 25 | 40 | 63 | 100 | 160 | 250 | |
R=125 | Q2(l/h) | 32 | 51.2 | 80.64 | 128 | 204.8 | 200 |
Q1(l/h) | 20 | 32 | 50.5 | 80 | 128 | ||
R=160 | Q2(l/h) | 22.5 | 40 | 63 | 100 | 160 | 400 |
Q1(l/h) | 15.62 | 25 | 39.37 | 62.5 | 100 | 250 | |
Max.Reading(m³) | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | |
Min.Reading(Liter) | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | |
Max.Pressure(Bar) | 16 | 16 | 16 | 16 | 16 | 16 | |
Pressure Loss | 63 | ||||||
Max.Temperature | T=50/90 | ||||||
Pulse Output Option | Vmax=24V | ||||||
Imax=100mA | |||||||
Pmax=2W |