Customization: | Available |
---|---|
After-sales Service: | Online/ Video/ on-Site Guidance and Training |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 40.15/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Feature
·Relative error
-Maximum permissible error between Q1 and Q2(excluded) is ±5% in flow low area.
-When the water temperature is not higher than 30ºC, maximum permissible error between Q2 and Q4(included) is ±2% in flow high area.
-When the water temperature is higher than 30ºC, maximum permissible error between Q2 and Q4(included) is ±3% in flow high area.
·Working temperature: cold water (0.1~30)ºC
·Operating ambient temperature: (5~55)ºC
·Storage environmental temperature: (‐5~55)ºC
Item | Unit | Details | ||
Nominal diameter | mm | 15 | 20 | 25 |
Q3/Q1 | R100 | |||
Overload flow(Q4) | m³/h | 3.125 | 5 | 7.875 |
Nominal flow(Q3) | m³/h | 2.5 | 4 | 6.3 |
Transitional flow(Q2) | m³/h | 0.04 | 0.064 | 0.1 |
Minimum flow(Q1) | m³/h | 0.025 | 0.04 | 0.063 |
Accuracy class | Class 2 | |||
Temperature class | T30/T50/T90 | |||
Pressure Loss classes | 0.63bar | |||
Flow prefile sensitivity class | U10/D5 | |||
environmental class | 0 | |||
Electromagnetic environment class | E1 |