Customization: | Available |
---|---|
After-sales Service: | Online/ Video/ on-Site Guidance and Training |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 55/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
An ultrasonic water meter is a device that uses ultrasonic technology to measure the flow rate and volume of water in a pipeline. The meter works by emitting high-frequency sound waves into the flowing water, which bounce off particles in the water and are detected by sensors in the meter. By measuring the time it takes for the sound waves to travel between the sensors, the meter can accurately determine the flow rate and volume of water. Ultrasonic water meters have several advantages over traditional mechanical meters, including greater accuracy, lower maintenance requirements, and the ability to measure both forward and reverse flow. They are commonly used in residential, commercial, and industrial applications for billing purposes and to optimize water usage.
Brief introduction
Ultrasonic water meter is a new type of water meter that detects the time difference caused by the change of velocity when the ultrasonic beam propagates in the opposite direction of the water, and analyzes and processes the flow rate of water to further calculate the flow of water.
The loss caused by the leakage of water supply pipe net is very alarming, especially when the pipelineburst suddenly.After the pipe burst, the loss in one hour is as highas 1250 cubic meters of water. if it can't be repaired in tlme, the burst water will wash the ground andcause the road collapse,which will cause casualties and property losses.
Our pipe network monitoring systerm can quickly locate the pipeline to be repaired and sond out the alarmmessage after the pipe burst. Our users can organize the ermergency repair at the first time to recover theloss and eliminate tho hiddon danger.
Features
·Material:brass
·Applicable scene:home,apartment,garden housing ,ground,commercial,residential building,malls,household portable,garden,domestic residential
·Technical data conform to international standard ISO 4064.
·Communication:rs485 modbus,LoRa
·Fitting:Pressure sensor,battery,lcd display,reading device,data logger,liquid turbine,user interface unit,reading device,actuator,connection fittings,Valve
·No mechanical movable parts,Impurities in water can't be affected, long service life and high accuracy
·Non-intrusive: Ultrasonic water meters are non-intrusive, meaning they do not require any cutting or drilling into pipelines to be installed.
·Accurate measurement: These meters use sound waves to accurately measure the flow rate of water, providing highly accurate readings.
·Low maintenance: Ultrasonic water meters have no moving parts, which means they require very little maintenance.
·Long lifespan: With no moving parts, ultrasonic water meters typically have a longer lifespan than other types of water meters.
·Wide range of flow rates: Ultrasonic water meters can measure a wide range of flow rates, making them suitable for both high and low flow scenarios.
·Tamper-proof: Ultrasonic water meters are difficult to tamper with since they rely on sound waves rather than physical components.
·Real-time data: Many ultrasonic water meters offer real-time data monitoring, allowing users to monitor their water usage in real-time.
Software advantages
1.High range ratio ultrasonic water rmeter.accurate measurement.
2.Fast feedback and accurate posltioning of emergency information.
Technical parameter
Item | Unit | Details | ||||
Nominal diameter | mm | 15 | 20 | 25 | 32 | 40 |
Q3/Q1 | R200 | |||||
Overlolad flow(Q4) | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 |
Nominal flow(Q3) | m³/h | 2.5 | 4 | 6.3 | 10 | 16 |
Transitional flow(Q2) | m³/h | 0.02 | 0.032 | 0.05 | 0.08 | 0.128 |
Minimum flow(Q1) | m³/h | 0.016 | 0.02 | 0.032 | 0.05 | 0.08 |
Accuracy class | Class2 | |||||
Battery life | 8years | |||||
Temperature class | T30/T50 | |||||
Pressure class | ≤0.063Mpa | |||||
Pressure loss class | ΔP63 | |||||
Flow prefile sensitivity class | U10/D5 | |||||
Environmental class | Class B,M1 | |||||
Electromagnetic environmrnt class | E1 | |||||
Working pressure | 1.6Mpa | |||||
Max flow indication(m³) | 9999999.9 | |||||
Installation position | Horizontal or Vertical |
Outline dimension
Nominal Diameter | Length L | Length L1 | WidthB | Height H1 | Connecting Thread | |
mm | d | D | ||||
DN15 | 258 | 165 | 95 | 95 | R1/R2 | G3/4B |
DN20 | 299 | 195 | 95 | 100 | R3/4 | G1B |
DN25 | 345 | 225 | 95 | 108 | R1 | G1 1/4B |
DN32 | 305 | 180 | 95 | 120 | R1 1/4 | G1 1/2B |
DN40 | 330 | 200 | 95 | 125 | R1 1/2 | G2B |